KENT CABLES PRIVATE LTD.
  Wires & Cables
Home / Wires & Cables   
 
     Arrow  WIRES & CABLES
 
  MULTICORE CIRCULAR PVC INSULATED COPPER CONDUCTOR AND SHEATHED CABLES IN VOLTAGE GRADE UP AND INCLUDING 1100V
 

 

Nominal cross sectional Area pf conductor Number/Nom. Dia of Wires* Thickness of Insulation (Nom)
 
Nominal Thickness of
Sheath
Approx Overall Diameter Dimension.
 
Current Rating AC Voltage DC/1OAC Drop 30 AC Resistance (Max.) Per Km. @20 0c
 
mm2 mm mm mm mm mm mm mm mm Amps mV mV Ohms
0.5 16/0.20 0.6 0.9 0.9 0.9 6.2 6.6 7.2 4 83 72 39.0
0.75 24/0.20 0.6 0.9 0.9 0.9 6.5 6.9 7.6 7 56 48 26.0
1.0 32/0.20 0.6 0.9 0.9 0.9 6.9 7.3 8.2 11 43 37 19.5
1.5 48/0.20 0.6 0.9 1.0 0.9 7.6 8.2 9.3 14 31 26 13.3
2.5 80/0.20 0.7 1.0 1.0 1.0 9.3 9.6 10.5 19 18 16 7.98
4.0 128/0.20 0.8 1.0 1.0 1.0 10.3 10.9 12.3 26 11 9.6 4.95
 

Note: Any colour on specific request can be supplied in 100 mtrs length in carton packing. As per 1s:694
         * The number and diameter pf conductor strands are for reference only. Conductor resistance as per 1s: 8130 is the
            governing criteria.

  FRLS Wires (Fire Retardant Low Smoke):
 

FRLS Wires are recommended for use in Fire Prime Zones and locations where the possibility of Short Circuit, Peep of Flame occur. The hazards of electrical fires are primarily:

  1. Thick Smoke barring vision.
  2. Strong pungent gas release choking eyes and lungs
  3. The burring fire itself.

KENT FRLS Wires are made from specially formulated and compounded PVC Polymer that retends the spread of flame, toxic gases and smoke as they are self extinguishing and do not allow the fire to spread.

FRLS Wires find most use in multistoried buildings, hotels, banquets, heavily equipped shops and commercial offices. Hospitals and Industrial control rooms with cluttered panels, instruments and areas where safety is the primary concern.

  Comparative Properties of Kent Wires
 
Feature Normal PVC Wire Heat Resistant HR-PVC Fire Retardant FR-PVC Fire Retardant Low Smoke FRLS Zero Halogen Low Smoke
Insulation Material PVC PVC Spl. PVC Spl. PVC Spl. Polymer

  Insulation Property

Normal Good Good Good Very Good

  Temperature Rating

70 Deg 0c 85 Deg 0c 70 Deg 0c 70 Deg 0c 85 Deg 0c

  Thermal Stability

Normal Very Good Good Good Very Good

  Flame Retardancy

Good Good Very Good Very Good Excellent

  Safety during Burning

Average Average Good Good Excellent

  Requirement of Oxygen To
  catch Fire (%in air)

>21 >21 >30 >30 >35

  Temperature Required To catch
  Fire (With 21% oxygen)

Room Temp. Room Temp. >250 Deg 0c >250 Deg 0c >300 Deg 0c

  Visibility during Cable Burning
  (%)

<20 <20 <35 <40 <80

  Release of Halogen Gas During
  Burning (% by weight)

<20 <20 <20 <20 Zero

  Abrasion Resistance During
  Installation

Good Good Good Good Good